WARNING
These products are intended for use in industrial
compressed air systems only. Do not use these products
where pressures and temperatures can exceed those listed
under Technical Data.
Before using these products with fluids other than air,
for nonindustrial applications, or for life-support systems
consult Norgren.
TECHNICAL DATA
Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature*: -20° to +65°C (0° to +150°F)
* Air supply must be dry enough to avoid ice formation at
temperatures below +2°C (+35°F).
Cv factor:
IN to OUT ports: 5,7
OUT to Exhaust ports on 3-port/2-position valves: 0,2
Exhaust port threads on T72T valves: M5 (10-32NF)
Materials:
Body: Zinc
Slide: Acetal plastic
Elastomers: Nitrile
REPLACEMENT ITEMS
Service Kits (includes items circled on exploded view)
T72B (Black slide) ..............................................4384-511
T72E (Yellow slide).............................................4384-513
T72T (Red slide).................................................4384-512
Exhaust silencer (T72T valves only) ........................MS000A
Exhaust diffuser (T72T valves only).......................54463-01
INSTALLATION
1. Install valve in air line with air flow in direction of arrow
on body. Use pipe thread sealant on male threads only.
Do not allow sealant to enter interior of valve.
2. The slide can be padlocked in the closed position only. If
desired, install a customer supplied padlock in the 5mm
(0.19") diameter hole in the slide.
DISASSEMBLY
1. Shut off inlet pressure. Reduce pressure in inlet and
outlet lines to zero.
2. Remove the valve from the air line. Disassemble in
general accordance with the item numbers on exploded
view.
CLEANING
1. Clean all parts with warm water and soap.
2. Dry and inspect parts. Replace parts found to be
damaged.
REASSEMBLY
1. Lubricate o-rings and center area of both sides of slide
(4) with o-ring grease. Assemble valve as shown on the
exploded view. The blade must be installed with the
words OPEN and CLOSED facing the inlet port. The
T72E valve uses o-ring (5) in the inlet and outlet bodies.
The T72B and T72T valves use o-ring (5) in the inlet
body, and seal (6) in the outlet body.
2. Torque Table
Item Torque in N-m (Inch-Pounds)
1 (Screw) 5,7 to 6,2 (50 to 55)
IM-160.600
(4/98)
a subsidiary of IMI plc
© Norgren 1998
2
4
3
1
1
6
5
T72
Installation & Maintenance
Instructions
Shut-off & Lockout Valves
T72 - ★★A- P1
Thread Form
A....PTF
B....ISO Rc taper
G....ISO G parallel
Type
B....2-Port/2-position shutoff valve, black slide, padlocks in closed position only
E....3-Port/2-position lockout valve, yellow slide, unthreaded exhaust outlet, padlocks in closed position only
T....3-Port/2-position shutoff valve, red slide, threaded exhaust port, padlocks in closed position only
Port
2....1/4"
3....3/8"
Options
N....None
D....T72T with exhaust diffuser
S....T72T with exhaust silencer