Norgren PRA/862000/M IVAC Industrial cylinder Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Norgren PRA/862000/M IVAC Industrial cylinder. Norgren PRA/862000/M IVAC Industrial cylinder User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
N/us 1.5.250.01
4/13
Our policy is one of continued research and development. We therefore reserve the right to amend,
without notice, the specifications given in this document.
© Norgren Americas 2013
PRA/862000/M
IVAC Industrial cylinder
double acting, magnetic piston
Ø 32 ... 100 mm
Cylinders and mountings conform to ISO 15552
Complete functional unit
Integrated 5/2 or 5/3 valve
Additional output cylinder ports (2 & 4)
Integrated flow regulator for speed control
Reed or solid state switches can be mounted
flush with the profile barrel
Protection class IP65
Energy efficient
13
7
Technical data
Materials:
Profile barrel:
anodised aluminum,
End covers: pressure diecast
anodised aluminum
Piston rod: stainless steel, see
page 2
Piston rod seals: polyurethane
Piston seals: polyurethane
O-rings: nitrile rubber
Medium:
Compressed air, filtered,
lubricated or non-lubricated
Particles size: Class 7,
ISO 8573 – 1 (dated 2001)
Humidity and water content:
Air supply must be dry.
Corresponding of the application
and working conditions the air
must be dry enough to avoid
condensate. The pressure
dewpoint must be minimum
15° under the application and
working conditions. Oil: Class
4, ISO 8573 – 1 (dated 2001)
Standard:
Based on ISO 15552
(length , mounting pitch and thread
dimensions according to ISO 15552. Some
outside dimensions different to ISO 15552)
Operation:
Double acting, magnetic piston,
adjustable cushioning
Operating pressure:
29 to 116 psig (2 to 8 bar)
Port size:
G1/8, G1/4, G3/8
Cylinder diameters:
32, 40, 50, 63, 80, 100 mm
Standard strokes:
See below
Non-standard strokes:
Available
25 to1000 mm
Operating temperature:
14° to 176°F (-10C to 80°C) max.
Supply voltage:
24 V d.c.
Power consumption:
2 W max
Electrical connection:
DIN EN175301-803, form C
Manual override:
Push and lock
Rating:
100 % continuous duty
Protection class:
IP 65
Technical features
Cylinder Ø (mm) 32 40 50 63 80 100
Air ports
G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 3/8
Piston rod Ø (mm)
12 16 20 20 25 25
Piston rod thread
M10 x 1.25 M12 x 1.25 M16 x 1.5 M16 x 1.5 M20 x 1.5 M20 x 1.5
Cushion length inch (mm)
0.74" (19) 0.86" (22) 0.94" (24) 0.94" (24) 1.06" (27) 1.34" (34)
Theoretical thrusts at 87 psig (6 bar) extended lbf. (N)
108 (482) 170 (754) 265 (1178) 420 (1870) 678 (3016) 1058 (4710)
Theoretical thrusts at 87 psig (6 bar) retracted lbf. (N)
93 (414) 142 (633) 223 (990) 378 (1680) 612 (2722) 993 (4416)
Air consumption at 87 psig (6 bar) extended cu ft/in (l/cm)
0.005 (0.056) 0.008 (0.088) 0.012 (0.137 0.019 (0.218) 0.031 (0.350) 0.059 (0.550)
Air consumption at 87 psig (6 bar)retracted cu ft/in (l/cm)
0.004 (0.050) 0.007 (0.076) 0.010 (0.117) 0.018 (0.198) 0.029 (0.324) 0.046 (0.514)
Cylinder
Ø (mm)
Strokes (mm)
25 50 80 100 125 160 200 250 320 400 500
32
40
50
63
80
100
Standard strokes
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - Standard strokes

N/us 1.5.250.014/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specificatio

Page 2

PRA/862000/MN/us 1.5.250.0104/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 3

PRA/862000/MN/us 1.5.250.0114/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 4

PRA/862000/MN/us 1.5.250.0124/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 5

PRA/862000/MN/us 1.5.250.0134/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 6

PRA/862000/MN/us 1.5.250.0144/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 7

PRA/862000/MN/us 1.5.250.024/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 8

PRA/862000/MN/us 1.5.250.034/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 9

PRA/862000/MN/us 1.5.250.044/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 10 - PRA/862000/M

PRA/862000/MN/us 1.5.250.054/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 11

PRA/862000/MN/us 1.5.250.064/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the

Page 12

PRA/862000/MN/us 1.5.250.074/13Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the